logo
خونه > محصولات >
تست کننده هپوتراپی ac dc
>
Professional Dielectric Loss Tester for Transformer Bushing Capacitor Insulation Performance Detection

Professional Dielectric Loss Tester for Transformer Bushing Capacitor Insulation Performance Detection

جزئیات محصول:
محل منبع: Xi'an ، Shaanxi ، چین
نام تجاری: XZH TEST
گواهی: ISO,CE
شماره مدل: XHJS1000R
اطلاعات دقیق
محل منبع:
Xi'an ، Shaanxi ، چین
نام تجاری:
XZH TEST
گواهی:
ISO,CE
شماره مدل:
XHJS1000R
محدوده اندازه گیری: tgδ:
0 تا 100 ± 1٪ + 0.040٪
CX:
15pF<Cx<300nF ±1%+1p 10kV<60nF 1kV<300nF تست CVT<300nF
L:
>20H(2kV) R>10kΩ(2kV) 0.1%
نسبت تبدیل CVT:
10 تا 10000
قطعنامه:
0.01
برجسته کردن:

High Light

برجسته کردن:

dielectric loss tester for transformers,transformer bushing capacitor tester,insulation performance tester with warranty

,

transformer bushing capacitor tester

,

insulation performance tester with warranty

Trading Information
مقدار حداقل تعداد سفارش:
1 واحد
قیمت:
قابل مذاکره
جزئیات بسته بندی:
بسته بندی چوبی
زمان تحویل:
5-8 روز کاری
شرایط پرداخت:
T/T
قابلیت ارائه:
2000 دور در سال
توضیحات محصول
Product Overview

XHJS1000R Dielectric Loss Tester applies digital notch technology to shield the test from power frequency electric field interference, which effectively addresses the challenge of precise measurement in strong electric field interference environments. The tester is compatible with generator power supply, and when matched with an oil cup and temperature control unit, it can conduct dielectric loss testing of insulating oil.

Performance Features
  • Integrated with built-in power supply, step-up transformer and standard capacitor;
  • Support for positive/reverse connection mode, internal/external standard capacitors, internal/external test voltage and self-excitation testing method;
  • Realize fully automatic detection of inductance, capacitance and resistance, with real-time angle display function;
  • Possess multiple protective mechanisms for input voltage fluctuation, high-voltage current, output short circuit, power fault, overvoltage, overcurrent, temperature abnormality, etc.
Technical Parameters
  • Measurement range: tgδ: 0~100% ±1%+0.040% Cx:15pF<Cx<300nF ±1%+1p 10kV<60nF 1kV<300nF CVT test<300nF
  • L:>20H(2kV) R>10kΩ(2kV) 0.1%
  • CVT transformation ratio Precision: 0.1% Resolution: 0.01
  • Insulation resistance: Error below 5% at 100kΩ-1000GΩ(250V) Error of 10% at 100GΩ-1000GΩ(10000V)
  • High-voltage output: 0.5KV~10KV/200mA ±2%
  • Service conditions: -15℃~40℃ Rh<80%
  • Working power supply: AC 220V±10%, generator power supply is permissible