XHDD503C+ Cable Fault Pinpointer

In the process of power cable fault detection, precise fault localization constitutes the most critical stage. The XHDD503C+ employs synchronous acoustic-magnetic localization technology—combining a high-sensitivity, fully digital probe with intelligent signal processing algorithms—to achieve precise localization of fault points, making it suitable for operation in a wide variety of complex working environments.

آخرین اخبار شرکت Cable Fault Pinpointer XHDD503C+ | Acoustic-Magnetic Synchronization | Path Guidance | Precise Localization  0

The XHDD503C+ Cable Fault Pinpointer is suitable for use with:
  • Power cables, coaxial cables, low-voltage cables, and electrical wires
  • Low-resistance faults, short circuits, open circuits, and broken conductors
  • High-resistance faults (both leakage-type and flashover-type)
  • Emergency fault repair for urban power distribution network cables
  • Fault pinpointing during inspections of high-voltage transmission cables
  • Open-circuit and short-circuit detection for low-voltage cables in industrial and mining enterprises
  • Fault localization for coaxial cables in rail transit and telecommunications systems

آخرین اخبار شرکت Cable Fault Pinpointer XHDD503C+ | Acoustic-Magnetic Synchronization | Path Guidance | Precise Localization  1

Technical Specifications
Positioning Accuracy:
≤ 0.1 m
Path Accuracy:
≤ 0.5 m
Detection Time Range:
0.00 – 99.99 ms
Audio Gain:
16 levels (0 – 112 dB)
Output Impedance:
350 Ω
Acoustic/Magnetic Channel Adjustment:
8 adjustable levels each
Trigger Threshold:
0 – 99 adjustable levels
Filtering Mode:
5th-order superimposed filtering
  • All-pass: 100 Hz – 1600 Hz
  • Band-pass: 200 Hz – 600 Hz
  • Low-pass: 100 Hz – 300 Hz
  • High-pass: 160 Hz – 1600 Hz
Noise Reduction Technology:
BNR Background Noise Reduction + Mute Noise Reduction

آخرین اخبار شرکت Cable Fault Pinpointer XHDD503C+ | Acoustic-Magnetic Synchronization | Path Guidance | Precise Localization  2

Key Features
  • Automatic calculation of acoustic-magnetic time differences eliminates the need for manual estimation.
  • Gain and trigger threshold settings support both automatic and manual modes.
  • Multiple filtering options are available to adapt to varying on-site noise environments.
  • Path deviation alerts and proximity indicators for fault points simplify operation and reduce difficulty.
  • Background noise reduction and mute-mode noise suppression enhance the discernibility of weak signals.
  • Portable design: the main unit weighs less than 1 kg, enabling a single operator to complete the entire workflow independently.
  • Features a highly sensitive, noise-resistant, fully digital fixed-point probe.

آخرین اخبار شرکت Cable Fault Pinpointer XHDD503C+ | Acoustic-Magnetic Synchronization | Path Guidance | Precise Localization  3

Application Scenarios
  • Emergency Repair of Urban Distribution Network Cables
  • High-Voltage Transmission Cable Line Patrol and Fault Pinpointing
  • Open-Circuit/Short-Circuit Detection for Low-Voltage Cables in Industrial and Mining Enterprises
  • Coaxial Cable Fault Localization